I am in the process of debugging inverter,I encountered a inverter,As long as the inverter starts, report the current,Check the motor,no problem,Then restore the factory setting value,Still as long as the inverter is started, the current is reported.,There is no way to replace a new inverter,Also 巴慕达加湿器在那修 equipped。Think:Inverter direct control motor,Start in the inverter operation panel,Inverter is new,The inverter is certainly no problem,Can only look at the motor wiring,Hold the mentality of trying a try,I looked at it.,Motor wiring has problems,It turns out that there is a line connected to the motor ground from the three-phase line output from the inverter.。Causes the 巴慕达烤箱在那修 inverter to report the current。
Recently visited Siemens website,Found the same problem,But the difference is the problem I have encountered,Human,The problem of motor windings he encountered,But we have encountered a common problem.,It is the alarm status.,The inverter is alarm。I have given my experience,There are other people's experience summary summary,I hope I can help everyone.,The future work encounters such a problem can be quickly solved!!!